PCR Single Tube, 0.2 ml, Flat Cap, Clear, Thin Wall, 1000/pk
0.2 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
PCR tubes in 0.1, 0.2 and 0.5 ml: single tubes with flat or convex caps, 8-tube strips with separate or hinged caps in clear or white, and 0.1 ml 4-tube strips.
They are used for PCR and qPCR in thermal cyclers, in packs of 125 to 1000. Items not in stock have a lead time of 3 to 4 weeks.
0.2 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.2 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.5 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.1 ml
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.1 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.1 ml, White
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.1 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.1 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.2 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.2 ml, White
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.2 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0.2 ml, Clear
Lead time 3-4 weeks, ships from the Czech Republic (EU)
No products match these filters.
Choose by volume and application first, then by cap, centrifuge rating and material.
| Tube | Volumes | Typical use |
|---|---|---|
| PCR tubes and strips | 0.1, 0.2 and 0.5 ml | PCR and qPCR in a thermal cycler |
| Microcentrifuge tubes | 0.5, 1.5, 2.0 and 5.0 ml | Small-volume spins, storage, sample prep |
| Conical centrifuge tubes | 10, 15 and 50 ml | Cell pellets, extractions, general lab work |
| Plastic test tubes | 5 to 15 ml (12 × 75 to 16 × 150 mm) | General testing and sample handling |
| Cryovials | 0.5 to 10 ml | Frozen storage at -80 °C or in liquid nitrogen vapour |
Every tube has a maximum RCF (× g). Tubes in this range are rated 8,000 to 15,000 × g. Your centrifuge shows rpm or × g; to convert, RCF = 1.118 × 10⁻⁵ × rotor radius in cm × rpm².
Polypropylene (PP) resists most chemicals and can be autoclaved at 121 °C. Polystyrene (PS) is clear and rigid but is not autoclavable and does not resist organic solvents; the plastic test tubes in this range are PS. Check the material on each product page.
Store cryovials in the vapour phase of liquid nitrogen rather than in the liquid, which can seep into a vial and expand on thawing. External-thread caps keep the threads away from the sample; internal-thread vials take less space in a box. Choose a cryovial box with the right well size for 1.8/2 ml, 5 ml, 10/15 ml or 50 ml tubes.
0.1 ml (low-profile) tubes fit low-profile and fast cycler blocks; 0.2 ml tubes fit standard blocks. Check your cycler before ordering.
White tubes reflect fluorescence back to the detector and reduce crosstalk, which helps in qPCR. Clear tubes let you see the liquid.
Flat caps are needed for optical reading in qPCR and are easy to label. Convex (domed) caps suit standard PCR.
Hinged caps stay attached to the strip, so they cannot get lost or mixed up. Separate cap strips let you open one strip without disturbing others.