Plastic Test Tube With Cap, PS, 12 × 75 mm(Assembled), 1000/pk
PS, 12 × 75 mm
Lead time 3-4 weeks, ships from the Czech Republic (EU)
Polystyrene test tubes with caps fitted (12 × 75, 12 × 100, 16 × 100 and 16 × 150 mm), plus plastic racks for 16 and 20 mm tubes, microtubes and 15 and 50 ml centrifuge tubes.
They come in packs of 10 to 1000. Items not in stock have a lead time of 3 to 4 weeks.
PS, 12 × 75 mm
Lead time 3-4 weeks, ships from the Czech Republic (EU)
PS, 16 × 100 mm
Lead time 3-4 weeks, ships from the Czech Republic (EU)
PS, 12 × 100 mm
Lead time 3-4 weeks, ships from the Czech Republic (EU)
PS, 16 × 150 mm
Lead time 3-4 weeks, ships from the Czech Republic (EU)
15 ml
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0
Lead time 3-4 weeks, ships from the Czech Republic (EU)
0
Lead time 3-4 weeks, ships from the Czech Republic (EU)
50 ml
Lead time 3-4 weeks, ships from the Czech Republic (EU)
No products match these filters.
Choose by volume and application first, then by cap, centrifuge rating and material.
| Tube | Volumes | Typical use |
|---|---|---|
| PCR tubes and strips | 0.1, 0.2 and 0.5 ml | PCR and qPCR in a thermal cycler |
| Microcentrifuge tubes | 0.5, 1.5, 2.0 and 5.0 ml | Small-volume spins, storage, sample prep |
| Conical centrifuge tubes | 10, 15 and 50 ml | Cell pellets, extractions, general lab work |
| Plastic test tubes | 5 to 15 ml (12 × 75 to 16 × 150 mm) | General testing and sample handling |
| Cryovials | 0.5 to 10 ml | Frozen storage at -80 °C or in liquid nitrogen vapour |
Every tube has a maximum RCF (× g). Tubes in this range are rated 8,000 to 15,000 × g. Your centrifuge shows rpm or × g; to convert, RCF = 1.118 × 10⁻⁵ × rotor radius in cm × rpm².
Polypropylene (PP) resists most chemicals and can be autoclaved at 121 °C. Polystyrene (PS) is clear and rigid but is not autoclavable and does not resist organic solvents; the plastic test tubes in this range are PS. Check the material on each product page.
Store cryovials in the vapour phase of liquid nitrogen rather than in the liquid, which can seep into a vial and expand on thawing. External-thread caps keep the threads away from the sample; internal-thread vials take less space in a box. Choose a cryovial box with the right well size for 1.8/2 ml, 5 ml, 10/15 ml or 50 ml tubes.
Yes, these tubes are supplied assembled with the cap fitted.
The combined rack holds 30 × 15 ml and 20 × 50 ml tubes; there is also a 25-place rack for 50 ml tubes only.
The microtube racks with 60 or 96 holes take 0.5, 1.5 and 2.0 ml microtubes.